P0490 Exhaust Gas Recirculation Control Circuit High Voltage

AutoHex Online Help: Hyundai i30(GDe) 2013
Component Location
General Description

Receiving ECM signal, linear solenoid type electronic EGR actuator operates Electric EGR control valve directly. ECM performs EGR system feed back control with the information of measured mass air flow (The role of MAFS in diesel engine is different from gasoline engine. Fuel injection quantity is decided by MAFS signal in gasoline engine.)

When EGR gas(contains no oxygen) flowing into combustion chamber increases, the air passing through AFS(contains oxygen) decreases. Thus, with the output signal change of AFS accompanied by Electric EGR control valve actuation, ECM determine the amount of recirculated EGR gas quantity.

note

NOx is produced from the reaction of nitrogen and oxygen.

Controlling EGR gas(contains no oxyger) which is recirculated to combustion chamber, if least intake air required for complete combustion flows into combustion chamber, NOx decreases because there is no supplementary oxygen to react with nitrogen.



DTC Description

P0490 is set when excessive current is detected in Electric EGR control valve circuit for more than 0.5 sec.. This code is due to short to battery in Electric EGR control valve control circuit or internal short in Electric EGR control valve component.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal monitoring

Electric EGR control

valve circuit

Electric EGR control

valve component

Enable Conditions

Engine run

Threshold Value

Short to battery.

Diagnostic Time

500ms

Fail Safe

Fuel cut

NO

EGR Off

YES

Fuel Limit

NO

MIL

NO

Specification

Electric EGR control valve

component resistance

Electric EGR control valve

operating Hz

Electric EGR control valve

operating duty

14.7 ~ 16.1O (20?)

142Hz

5%(closed)~39%(opened)

Diagnostic Circuit Diagram
Signal Waveform

Fig.1) Approx. 5% duty signal waveform of Electric EGR control valve (with EEGR valve closed)

Fig.2) Approx. 57% duty signal waveform of Electric EGR control valve(with EEGR valve opened)

note

The output of approx. 5% duty is mainly for the diagnosis of Electric EGR control valve circuit than actuating EEGR.