P0748 Pressure Control Solenoid Valve(VFS) "A" Electrical

AutoHex Online Help: Hyundai i10(PA) 2012
Component Location
General Description

Pressure Control Solenoid (Linear Solenoid) : With the duty control which uses higher frequency(600Hz), instead of the existing PWM type which adapts low frequency(60Hz) to control,spool valve can be conrolled precisely.

In PWM control,the amount of oil flow is determined by the duration of "ON"signal among continuously repeated ON/OFF signals.

In Pressure Control, the amount is decided by how widely spool valve open the passage of going through.



DTC Description

The TCM checks the Pressure Control Signal by monitoring the feedback signal from the solenoid valve drive circuit. If an unexpected signal is monitored (for example, high voltage is detected when low voltage is expected, or low voltage is detected when high voltage is expected), the TCM judges that the Pressure control solenoid valve circuit is malfunctioning and sets this code.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Check feed back period

Open or short in circuit

Faulty VF SOLENOID VALVE

Faulty PCM/TCM

Enable Conditions

16V > Actuator(TCU) power supply voltage >10V

Threshold Value

Circuit open or short to ground

Diagnostic Time

More than 1sec

Fail Safe

Locked in 3 rd gear.

Specification

Solenoid Valve for Pressure Control

- Sensor type : Normal open 3-way

- Operating temperature : -30°C~130°C

- Frequency :PCSV-A,B,C,D :50Hz (at the ATF temp. -20°C above)

VFS : 400~1000

? KM series : 35Hz

- Internal resistance : 3.5 ± 0.2 ?(20°C)

- Surge voltage : 56 V

Schematic Diagram
Signal Waveform

Fig 1) Waveform from "Pressure Control Solenoid"