Fuel Temperature Sensor is NTC thermistor installed in fuel supplying line. It senses the temperature of fuel supplied to high pressure pump.
Fuel temperature is limited (engine power is limited) to keep fuel temperature from reaching at 120?.
This limit is to protect fuel line such as high pressure pump and injectors from damages due to rapid deterioration by vapor-lock phenomenon which can occur at high temperature or destruction of oil membrane.
P0182 is set when the voltage below 0.053V - minimum voltage of FTS output - is detected for more than 2.0 sec.. This code is due to short to ground in FTS signal circuit.
Item
Detecting Condition
Possible Cause
DTC Strategy
? Voltage monitoring
? FTS circuit
? FTS component
Enable Conditions
? IG KEY "ON"
Threshold Value
? When output signal is below the minimum value.(below 53mV)
Diagnostic Time
? 2.0 sec.
Fail Safe
Fuel Cut
NO
? Fuel temp. fixed at 85?
EGR Off
Fuel Limit
Check Lamp
Temperature
- 30?
- 20?
-10?
0?
20?
Resistance
22.22~31.78?
13.24~18.10?
8.16~10.74?
5.18~6.60?
2.27~2.73?
40?
50?
60?
70?
1.059~1.281?
0.748~0.904?
0.538~0.650?
0.392~0.476?