Follow us on Twitter and win Autohex II Scan Tool for Kia and Hyundai (worth 945.00 USD)

P0765 Overdrive Solenoid Valve Circuit - Open or Short(GND)

AutoHex Online Help: Hyundai SONATA(NF) 2005
Component Location
General Description

The Automatic Transmission changes the gear position of the transmission utilizing a combination of Clutches and Brakes, which are controlled by solenoid valves. The HIVEC Automatic Transmission consists of a: LR ( Low and Reverse Brake ), 2ND ( 2nd Brake ), UD ( Under Drive Clutch ), OD ( Over Drive Clutch ), REV ( Reverse Clutch ), and RED ( Reduction Brake, only for 5 speed transmissions). The OD Clutch is engaged in the 3rd gear and 4th gear positions.



DTC Description

The TCM checks the Under Drive Clutch Control Signal by monitoring the feedback signal from the solenoid valve drive circuit. If an unexpected signal is monitored (for example, high voltage is detected when low voltage is expected or low voltage is detected when high voltage is expected), the TCM judges that the OVER DRIVE CLUTCH drive control solenoid circuit is malfunctioning and sets this code.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

CASE1

DTC Strategy

? Check voltage range

? Open or short in circuit

? Faulty OD SOLENOID VALVE

? Faulty PCM/TCM

Enable Conditions

? 16V > Voltage Battery >10V

Threshold Value

? Feedback voltage from 2nd control solenoide>vb-2V and 2nd control duty is 0%

? Feedback voltage from 2nd control solenoide=5.5V and 2nd control duty is 100%

Diagnostic Time

? More than 320 ms

Fail Safe

? Locked in 3 rd gear.(Control relay off)

CASE2

DTC Strategy

? Check voltage range

Enable Conditions

? Voltage Battery >10V

? OIL TEMP. = -23.5?

? 2nd gear and not under the down shifting

? Ne = 450rpm

? No > 100rpm

? Nt > 0rpm

? Inhibitor switch is normal and after 2sec is passed from IG ON

Threshold Value

??input speed/3rd gear ratio - output speed ?= 50rpm

Diagnostic Time

? More than 320 ms

Fail Safe

? Locked in 3 rd gear.(Control relay off)

Specification

Solenoid Valve for Pressure Control

- Sensor type : Normal open 3-way

- Operating temperature : -22~266?(-30?~130?)

- Frequency : LR, 2ND, UD, OD, RED : 61.27Hz (at the ATF temp. -20? above)

DCC : 30.64Hz

? KM series : 35Hz

- Internal resistance : 2.7~3.4O(20?)

- Surge voltage : 56 V

Schematic Diagram